Devices used to measure force-time characteristics of spinal manipulations and mobilizations: A mixed-methods scoping review on metrologic properties and factors influencing use

Téléchargements

Téléchargements par mois depuis la dernière année

Mercier, M.-A., Rousseau, P., Funabashi, M., Descarreaux, M. et Pagé, I. (2021). Devices used to measure force-time characteristics of spinal manipulations and mobilizations: A mixed-methods scoping review on metrologic properties and factors influencing use. Frontiers in Pain Research, 2 (83). ISSN 2673-561X DOI 10.3389/fpain.2021.755877

[thumbnail of DESCARREAUX_M_291_ED.pdf]
Prévisualisation
PDF
Télécharger (1MB) | Prévisualisation

Résumé

Background: Spinal manipulations (SMT) and mobilizations (MOB) are interventions commonly performed by many health care providers to manage musculoskeletal conditions. The clinical effects of these interventions are believed to be, at least in part, associated with their force-time characteristics. Numerous devices have been developed to measure the force-time characteristics of these modalities. The use of a device may be facilitated or limited by different factors such as its metrologic properties.Objectives: This mixed-method scoping review aimed to characterize the metrologic properties of devices used to measure SMT/MOB force-time characteristics and to determine which factors may facilitate or limit the use of such devices within the context of research, education and clinical practice. Methods: This study followed the Joanna Briggs Institute's framework. The literature search strategy included four concepts: (1) devices, (2) measurement of SMT or MOB force-time characteristics on humans, (3) factors facilitating or limiting the use of devices, and (4) metrologic properties. Two reviewers independently reviewed titles, abstracts and full articles to determine inclusion. To be included, studies had to report on a device metrologic property (e.g., reliability, accuracy) and/or discuss factors that may facilitate or limit the use of the device within the context of research, education or clinical practice. Metrologic properties were extracted per device. Limiting and facilitating factors were extracted and themes were identified. Results: From the 8,998 studies initially retrieved, 46 studies were finally included. Ten devices measuring SMT/MOB force-time characteristics at the clinician-patient interface and six measuring them at patient-table interfaces were identified. Between zero and eight metrologic properties were reported per device: measurement error (defined as validity, accuracy, fidelity, or calibration), reliability/repeatability, coupling/crosstalk effect, linearity/correlation, sensitivity, variability, drift, and calibration. From the results, five themes related to the facilitating and limiting factors were developed: user-friendliness and versatility, metrologic/intrinsic properties, cost and durability, technique application, and feedback. Conclusion: Various devices are available to measure SMT/MOB force-time characteristics. Metrologic properties were reported for most devices, but terminology standardization is lacking. The usefulness of a device in a particular context should be determined considering the metrologic properties as well as other potential facilitating and limiting factors.

Type de document: Article
Mots-clés libres: manual therapy (MT) spinal manipulation HVLA mobilization metrologic properties qualitatitve research methods scoping review limiting factor (s) faciliting factors mixed-methods force-time characteristics
Date de dépôt: 22 nov. 2021 15:58
Dernière modification: 22 nov. 2021 15:58
Version du document déposé: Version officielle de l'éditeur
URI: https://depot-e.uqtr.ca/id/eprint/9805

Actions (administrateurs uniquement)

Éditer la notice Éditer la notice