Measuring up: A comparison of TapeStation 4200 and Bioanalyzer 2100 as measurement tools for RNA quality in postmortem human brain samples

Téléchargements

Téléchargements par mois depuis la dernière année

Walker, J. E., Oliver, J. C., Stewart, A. M., Beh, S. T., Arce, R. A., Glass, M. J., Vargas, D. E., Qiji, S. H., Intorcia, A. J., Borja, C. I., Cline, M. P., Hemmingsen, S. J., Krupp, A. N., McHattie, R. D., Mariner, M. R., Lorenzini, I., Aslam, S., Tremblay, C., Beach, T. G. et Serrano, G. E. (2023). Measuring up: A comparison of TapeStation 4200 and Bioanalyzer 2100 as measurement tools for RNA quality in postmortem human brain samples. International Journal of Molecular Sciences, 24 (18). Article 13795. ISSN 1661-6596 1422-0067 DOI 10.3390/ijms241813795

[thumbnail of TREMBLAY, C_18_ED.pdf]
Prévisualisation
PDF
Disponible sous licence Creative Commons Attribution.

Télécharger (879kB) | Prévisualisation

Résumé

Abstract

The determination of RNA integrity is a critical quality assessment tool for gene expression studies where the experiment’s success is highly dependent on the sample quality. Since its introduction in 1999, the gold standard in the scientific community has been the Agilent 2100 Bioanalyzer’s RNA integrity number (RIN), which uses a 1–10 value system, from 1 being the most degraded, to 10 being the most intact. In 2015, Agilent launched 4200 TapeStation’s RIN equivalent, and reported a strong correlation of r2 of 0.936 and a median error < ±0.4 RIN units. To evaluate this claim, we compared the Agilent 4200 TapeStation’s RIN equivalent (RINe) and DV200 to the Agilent 2100 Bioanalyzer’s RIN for 183 parallel RNA samples. In our study, using RNA from a total of 183 human postmortem brain samples, we found that the RIN and RINe values only weakly correlate, with an r2 of 0.393 and an average difference of 3.2 RIN units. DV200 also only weakly correlated with RIN (r2 of 0.182) and RINe (r2 of 0.347). Finally, when applying a cut-off value of 6.5 for both metrics, we found that 95.6% of samples passed with RIN, while only 23.5% passed with RINe. Our results suggest that even though RIN (Bioanalyzer) and RINe (TapeStation) use the same 1–10 value system, they should not be used interchangeably, and cut-off values should be calculated independently.

Type de document: Article
Mots-clés libres: RNA integrity number 2100 Bioanalyzer 4200 TapeStation DV200 Sequencing
Date de dépôt: 25 sept. 2026 12:15
Dernière modification: 25 sept. 2026 12:15
Version du document déposé: Version officielle de l'éditeur
URI: https://depot-e.uqtr.ca/id/eprint/13138

Actions (administrateurs uniquement)

Éditer la notice Éditer la notice